{"product_id":"aims-7000w-48v-240v-industrial-inverter","title":"AIMS 7000W 48V 240V Industrial Inverter","description":"\u003cdiv style=\"width: 100%; color: #1b2520; line-height: 1.65; font-size: 18px;\"\u003e\n\u003c!-- HOOK --\u003e\n\u003ch2 style=\"font-size: clamp(1.6rem,5.5vw,2.2rem); line-height: 1.2; margin: 6px 0 10px;\"\u003e7000 Watts of 240V AC From a 48V Battery — Industrial-Grade Build, 9-Second Surge, and Selectable 50\/60Hz for Maximum System Efficiency\u003c\/h2\u003e\n\u003cp style=\"font-size: clamp(1.1rem,3vw,1.3rem); color: #5b6b63; font-weight: 500; margin: 0 0 16px;\"\u003eResettable external circuit breakers, a percent-load LED bar, a DC input voltmeter, and 154°F thermal tolerance — built for high-vibration environments, extreme temperatures, and loads that demand more than a standard consumer inverter can deliver.\u003c\/p\u003e\n\u003c!-- INTRO --\u003e\n\u003cp style=\"margin: 8px 0 14px;\"\u003eThe\u003cstrong\u003e \u003c\/strong\u003eAIMS Power 7000 Watt Industrial Grade Modified Sine Wave Inverter (PWRIG700024048) converts 48V DC battery power into single-phase 240V AC at a continuous 7000 watts — with 14,000-watt surge capacity electronically sustained for up to 9 seconds, far beyond the millisecond surge window of standard consumer inverters. Operating at 48V reduces DC current draw and allows smaller cable and multiple-battery configurations compared to lower-voltage equivalents. Designed for high-vibration installations and extreme operating temperatures, this is the inverter of choice for well pumps, large compressors, job-site power, and industrial equipment. A selectable 50\/60Hz frequency switch makes it equally at home in North American, European, African, and other international 240V applications.\u003c\/p\u003e\n\u003cdiv style=\"background: #fff8f1; border: 1px solid #f3d9bd; border-radius: 14px; padding: 14px 16px; font-size: 1rem; color: #6b4318; margin: 16px 0;\"\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e This inverter outputs single-phase 240V AC only. It is NOT a split-phase unit — you cannot pull one leg of 120V from it. It requires a 48V DC input and will not operate on a 12V or 24V battery system. For 120V AC applications, see AIMS Power's standard inverter range.\u003c\/div\u003e\n\u003c!-- TRUST BADGES --\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 8px; margin: 18px 0 0;\"\u003e\n\u003cspan style=\"font-size: 0.92rem; font-weight: 600; background: #f6f8f6; border: 1px solid #e3e8e4; color: #0a4a36; padding: 8px 13px; border-radius: 999px;\"\u003eAuthorized AIMS Power Dealer\u003c\/span\u003e \u003cspan style=\"font-size: 0.92rem; font-weight: 600; background: #f6f8f6; border: 1px solid #e3e8e4; color: #0a4a36; padding: 8px 13px; border-radius: 999px;\"\u003eIndustrial Grade\u003c\/span\u003e \u003cspan style=\"font-size: 0.92rem; font-weight: 600; background: #f6f8f6; border: 1px solid #e3e8e4; color: #0a4a36; padding: 8px 13px; border-radius: 999px;\"\u003e50\/60 Hz Selectable\u003c\/span\u003e \u003cspan style=\"font-size: 0.92rem; font-weight: 600; background: #f6f8f6; border: 1px solid #e3e8e4; color: #0a4a36; padding: 8px 13px; border-radius: 999px;\"\u003e1-Year Warranty Parts \u0026amp; Labor\u003c\/span\u003e \u003ca style=\"font-size: 0.92rem; font-weight: 600; background: #f6f8f6; border: 1px solid #e3e8e4; color: #0a4a36; padding: 8px 13px; border-radius: 999px; text-decoration: none; display: inline-block;\" rel=\"noopener noreferrer\" href=\"https:\/\/www.truesteadsupply.com\/policies\/shipping-policy\" target=\"_blank\"\u003eFree Shipping\u003c\/a\u003e\n\u003c\/div\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #e3e8e4; margin: 34px 0;\"\u003e\n\u003c!-- KEY FEATURES \u0026 BENEFITS --\u003e\n\u003ch2 style=\"font-size: clamp(1.6rem,5.5vw,2.2rem); line-height: 1.2; margin: 6px 0 10px;\"\u003eKey Features \u0026amp; Benefits\u003c\/h2\u003e\n\u003cp style=\"margin: 8px 0 14px;\"\u003eThe PWRIG700024048 brings the 7000W industrial platform to 48V systems — combining the lower DC current advantages of 48V operation with industrial-grade thermal tolerance, an electronically extended surge window, and field-practical monitoring and protection features.\u003c\/p\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 14px; margin: 16px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; background: #f6f8f6; border: 1px solid #e3e8e4; border-radius: 14px; padding: 18px;\"\u003e\n\u003cspan style=\"display: block; font-size: 1.65rem; font-weight: 800; color: #0f6b4f; line-height: 1.1; margin-bottom: 4px;\"\u003e9-Second Surge\u003c\/span\u003e\n\u003ch4 style=\"font-size: 1.15rem; margin: 0 0 6px; color: #0a4a36;\"\u003eExtended 14,000W Surge Capacity\u003c\/h4\u003e\n\u003cp style=\"margin: 0; font-size: 1.05rem; color: #5b6b63;\"\u003eWhere standard inverters sustain surge power for milliseconds, this industrial-grade unit holds up to 14,000 watts for a full 9 seconds — giving air conditioners, large compressors, well pumps, and electric motors the extended inrush current window they actually need to start.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; background: #f6f8f6; border: 1px solid #e3e8e4; border-radius: 14px; padding: 18px;\"\u003e\n\u003cspan style=\"display: block; font-size: 1.65rem; font-weight: 800; color: #0f6b4f; line-height: 1.1; margin-bottom: 4px;\"\u003e48V Efficient\u003c\/span\u003e\n\u003ch4 style=\"font-size: 1.15rem; margin: 0 0 6px; color: #0a4a36;\"\u003eLower DC Current, Smaller Cables\u003c\/h4\u003e\n\u003cp style=\"margin: 0; font-size: 1.05rem; color: #5b6b63;\"\u003eOperating at 48V significantly reduces DC current draw compared to a 24V equivalent at the same output — allowing smaller-gauge cable and multiple-battery configurations while reducing cable losses and heat.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; background: #f6f8f6; border: 1px solid #e3e8e4; border-radius: 14px; padding: 18px;\"\u003e\n\u003cspan style=\"display: block; font-size: 1.65rem; font-weight: 800; color: #0f6b4f; line-height: 1.1; margin-bottom: 4px;\"\u003e50 \/ 60 Hz\u003c\/span\u003e\n\u003ch4 style=\"font-size: 1.15rem; margin: 0 0 6px; color: #0a4a36;\"\u003eSelectable Output Frequency\u003c\/h4\u003e\n\u003cp style=\"margin: 0; font-size: 1.05rem; color: #5b6b63;\"\u003eA front-panel frequency switch toggles between 60Hz (North American standard) and 50Hz (European, African, and most international standards) — making this inverter deployable in any 240V power environment worldwide without additional hardware.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; background: #f6f8f6; border: 1px solid #e3e8e4; border-radius: 14px; padding: 18px;\"\u003e\n\u003cspan style=\"display: block; font-size: 1.65rem; font-weight: 800; color: #0f6b4f; line-height: 1.1; margin-bottom: 4px;\"\u003eDC Volt Meter\u003c\/span\u003e\n\u003ch4 style=\"font-size: 1.15rem; margin: 0 0 6px; color: #0a4a36;\"\u003eFront-Panel Battery Voltage Display\u003c\/h4\u003e\n\u003cp style=\"margin: 0; font-size: 1.05rem; color: #5b6b63;\"\u003eA dedicated DC input voltmeter gives you a direct, continuous readout of your 48V battery bank's condition — helping you monitor state of charge and avoid running too close to the low-voltage shutdown threshold.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; background: #f6f8f6; border: 1px solid #e3e8e4; border-radius: 14px; padding: 18px;\"\u003e\n\u003cspan style=\"display: block; font-size: 1.65rem; font-weight: 800; color: #0f6b4f; line-height: 1.1; margin-bottom: 4px;\"\u003eResettable CBs\u003c\/span\u003e\n\u003ch4 style=\"font-size: 1.15rem; margin: 0 0 6px; color: #0a4a36;\"\u003eExternal Resettable Circuit Breakers\u003c\/h4\u003e\n\u003cp style=\"margin: 0; font-size: 1.05rem; color: #5b6b63;\"\u003eExternally located resettable circuit breakers let you restore operation after an overload or fault without tools and without opening the unit — a key practical advantage in field and job-site installations where fast recovery matters.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 260px; background: #f6f8f6; border: 1px solid #e3e8e4; border-radius: 14px; padding: 18px;\"\u003e\n\u003cspan style=\"display: block; font-size: 1.65rem; font-weight: 800; color: #0f6b4f; line-height: 1.1; margin-bottom: 4px;\"\u003eLoad LED Bar\u003c\/span\u003e\n\u003ch4 style=\"font-size: 1.15rem; margin: 0 0 6px; color: #0a4a36;\"\u003ePercent Load Usage Display\u003c\/h4\u003e\n\u003cp style=\"margin: 0; font-size: 1.05rem; color: #5b6b63;\"\u003eA front-panel LED bar graph shows load as a percentage of the inverter's capacity in real time — giving operators an at-a-glance view of how much headroom remains before reaching the 7000W continuous limit.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- IMAGE SLOT 1: front face of PWRIG700024048 showing DC volt meter, load LED bar, LED indicators, circuit breakers, frequency switch, and outlet --\u003e \u003cimg style=\"width: 100%; max-width: 600px; height: auto; border-radius: 14px; display: block; margin: 8px auto 18px;\" loading=\"lazy\" alt=\"AIMS Power PWRIG700024048 7000 watt 48V 240V industrial grade modified sine inverter front panel DC volt meter load LED bar resettable circuit breakers frequency switch\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0761\/5781\/2888\/files\/pwrig700024048ACsideyahoo.webp?v=1781262168\"\u003e\n\u003ch3 style=\"font-size: clamp(1.3rem,3.5vw,1.55rem); line-height: 1.25; margin: 26px 0 8px;\"\u003eBuilt for High-Vibration and Extreme Environments\u003c\/h3\u003e\n\u003cp style=\"margin: 8px 0 14px;\"\u003eThe PWRIG700024048's rugged aluminum case is designed to withstand the vibration and thermal stress of engine compartments, construction vehicles, industrial facilities, and remote installations where standard consumer-grade inverters fail prematurely. The thermally controlled fan activates automatically at 107°F — engaging only when needed to conserve power during lighter loads — and the unit sustains full operation up to 154°F before automatic thermal shutdown. PWM programming continuously corrects for voltage and frequency fluctuations caused by battery state changes and sudden load surges, producing a stable, low-distortion output.\u003c\/p\u003e\n\u003ch3 style=\"font-size: clamp(1.3rem,3.5vw,1.55rem); line-height: 1.25; margin: 26px 0 8px;\"\u003eDual Output Connections: Outlet + Terminal Block\u003c\/h3\u003e\n\u003cp style=\"margin: 8px 0 14px;\"\u003eA single universal 240V AC receptacle handles plug-in loads, while the direct-connect AC terminal block allows hardwiring for full-load applications — pulling the complete 7000W continuous output to a permanently installed pump, compressor, or panel. The standard 240V outlet is limited to approximately 1500W; use the terminal block for any load above that. A pre-wired remote on\/off switch port lets you control the inverter from a remote location without accessing the unit.\u003c\/p\u003e\n\u003c!-- IMAGE SLOT 2: DC input side showing terminal block, mounting plate, and cable connections --\u003e \u003cimg style=\"width: 100%; max-width: 600px; height: auto; border-radius: 14px; display: block; margin: 8px auto 18px;\" loading=\"lazy\" alt=\"AIMS Power PWRIG700024048 7000 watt 48V industrial grade inverter DC input side AC terminal block mounting plate cable connections\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0761\/5781\/2888\/files\/pwrig700024048DCsideyahoo.webp?v=1781262168\"\u003e\u003chr style=\"border: 0; border-top: 1px solid #e3e8e4; margin: 34px 0;\"\u003e\n\u003c!-- WHO IT'S FOR --\u003e\n\u003ch2 style=\"font-size: clamp(1.6rem,5.5vw,2.2rem); line-height: 1.2; margin: 6px 0 10px;\"\u003eWho the AIMS Power 7000W 48V Industrial Inverter Is For\u003c\/h2\u003e\n\u003cul style=\"margin: 8px 0 14px; padding-left: 22px;\"\u003e\n\u003cli style=\"margin: 6px 0;\"\u003e\n\u003cstrong\u003eOff-grid cabin and homestead owners\u003c\/strong\u003e with a 48V battery bank who need to run a 240V well pump, large compressor, or whole-house power and require the extended surge time to start heavy motor loads.\u003c\/li\u003e\n\u003cli style=\"margin: 6px 0;\"\u003e\n\u003cstrong\u003eLarger off-grid solar installations\u003c\/strong\u003e already standardized on 48V architecture, where this inverter's lower DC current draw simplifies cable sizing at 7000W output.\u003c\/li\u003e\n\u003cli style=\"margin: 6px 0;\"\u003e\n\u003cstrong\u003eConstruction and job-site operators\u003c\/strong\u003e who need 240V AC for large power tools, compressors, and equipment in high-vibration and high-heat environments where consumer inverters aren't durable enough.\u003c\/li\u003e\n\u003cli style=\"margin: 6px 0;\"\u003e\n\u003cstrong\u003eIndustrial and commercial installers\u003c\/strong\u003e deploying inverters in machinery, vehicles, or facilities where thermal tolerance above standard consumer limits and resettable circuit breakers are required.\u003c\/li\u003e\n\u003cli style=\"margin: 6px 0;\"\u003e\n\u003cstrong\u003eInternational and European\/African off-grid system builders\u003c\/strong\u003e who need a 240V inverter switchable between 50Hz and 60Hz to match their local power standard from a 48V battery bank.\u003c\/li\u003e\n\u003cli style=\"margin: 6px 0;\"\u003e\n\u003cstrong\u003eAgricultural operators\u003c\/strong\u003e who need to run irrigation pumps, livestock equipment, or 240V machinery from a solar or battery bank at a remote site with no grid connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #e3e8e4; margin: 34px 0;\"\u003e\n\u003c!-- WHAT'S INCLUDED --\u003e\n\u003ch2 style=\"font-size: clamp(1.6rem,5.5vw,2.2rem); line-height: 1.2; margin: 6px 0 10px;\"\u003eWhat's Included\u003c\/h2\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; gap: 14px; margin: 16px 0;\"\u003e\n\u003cdiv style=\"flex: 1 1 250px; background: #f6f8f6; border: 1px solid #e3e8e4; border-radius: 14px; padding: 18px;\"\u003e\n\u003ch4 style=\"font-size: 1.15rem; margin: 0 0 8px; color: #0a4a36;\"\u003eIn the Box\u003c\/h4\u003e\n\u003cul style=\"margin: 0; padding-left: 20px; font-size: 1.05rem;\"\u003e\n\u003cli style=\"margin: 5px 0;\"\u003eAIMS Power PWRIG700024048 7000W Industrial Inverter (×1)\u003c\/li\u003e\n\u003cli style=\"margin: 5px 0;\"\u003eInstruction Manual\u003c\/li\u003e\n\u003cli style=\"margin: 5px 0;\"\u003ePre-slotted mounting plate (integrated on unit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 250px; background: #f6f8f6; border: 1px solid #e3e8e4; border-radius: 14px; padding: 18px;\"\u003e\n\u003ch4 style=\"font-size: 1.15rem; margin: 0 0 8px; color: #0a4a36;\"\u003eSold Separately\u003c\/h4\u003e\n\u003cul style=\"margin: 0; padding-left: 20px; font-size: 1.05rem;\"\u003e\n\u003cli style=\"margin: 5px 0;\"\u003eDC battery cables with lugged ends (required)\u003c\/li\u003e\n\u003cli style=\"margin: 5px 0;\"\u003eInline ANL fuse (recommended)\u003c\/li\u003e\n\u003cli style=\"margin: 5px 0;\"\u003eRemote on\/off switch (optional accessory)\u003c\/li\u003e\n\u003cli style=\"margin: 5px 0;\"\u003e48V deep-cycle or lithium battery bank\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"background: #fff8f1; border: 1px solid #f3d9bd; border-radius: 14px; padding: 14px 16px; font-size: 1rem; color: #6b4318; margin: 16px 0;\"\u003e\n\u003cstrong\u003eInstallation note:\u003c\/strong\u003e For full 7000W load operation, use the AC direct-connect terminal block rather than the standard 240V outlet (rated for approximately 1500W). DC battery cables are required and sold separately. An inline ANL fuse on the positive cable is recommended. Connect to a 48V battery bank only — this inverter requires 42–60V DC and will not operate on 12V or 24V systems. Set the frequency switch to 60Hz for North American use or 50Hz for European\/African\/international applications before connecting loads.\u003c\/div\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #e3e8e4; margin: 34px 0;\"\u003e\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2 style=\"font-size: clamp(1.6rem,5.5vw,2.2rem); line-height: 1.2; margin: 6px 0 10px;\"\u003eAIMS Power PWRIG700024048 Specifications\u003c\/h2\u003e\n\u003ch4 style=\"font-size: 1.15rem; margin: 18px 0 6px; color: #0a4a36;\"\u003eOutput\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 1.05rem; border: 1px solid #e3e8e4; border-radius: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top;\"\u003eContinuous Output Power\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top;\"\u003e7,000 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eSurge \/ Peak Power\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e14,000 Watts — electronically sustained for up to 9 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eOutput Voltage\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e240V AC ± 10% (single phase only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eOutput Waveform\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eModified Sine Wave with Phase Correction (PWM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eOutput Frequency\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e50 Hz or 60 Hz ± 1 Hz — selectable via front-panel switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eAC Output Socket Type\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e1× universal 240V AC receptacle + AC direct-connect terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eStartup AC Amps\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e58A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eContinuous AC Amps\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e29A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eFull Load Efficiency\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"font-size: 1.15rem; margin: 18px 0 6px; color: #0a4a36;\"\u003eInput\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 1.05rem; border: 1px solid #e3e8e4; border-radius: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top;\"\u003eDC Input Voltage Range\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top;\"\u003e42–60V DC (nominal 48V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eNo-Load Current Draw\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e0.18A DC (fan off); 0.66A DC (fan on)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eHigh Input Voltage Protection\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e60V ± 0.5V (shutdown)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eLow Voltage Alarm\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e42V ± 0.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eLow Voltage Shutdown\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e41.5V ± 0.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eDC Input Monitoring\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eFront-panel DC voltmeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4 style=\"font-size: 1.15rem; margin: 18px 0 6px; color: #0a4a36;\"\u003eThermal \u0026amp; Environment\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 1.05rem; border: 1px solid #e3e8e4; border-radius: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top;\"\u003eCooling Fan Activates At\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top;\"\u003e107°F (42°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eMax Operating Temp (Full Load)\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e154°F (68°C) — auto shutdown above this\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- DIMENSIONS \u0026 WEIGHT --\u003e\n\u003ch4 style=\"font-size: 1.15rem; margin: 18px 0 6px; color: #0a4a36;\"\u003eDimensions \u0026amp; Weight\u003c\/h4\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 1.05rem; border: 1px solid #e3e8e4; border-radius: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top;\"\u003eUnit Dimensions (D × W × H)\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top;\"\u003e22.5 × 10.0 × 6.5 in (57.2 × 25.4 × 16.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"text-align: left; width: 44%; padding: 11px 13px; background: #f6f8f6; font-weight: 600; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003eUnit Weight\u003c\/th\u003e\n\u003ctd style=\"text-align: left; padding: 11px 13px; vertical-align: top; border-top: 1px solid #e3e8e4;\"\u003e31 lb (14.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #e3e8e4; margin: 34px 0;\"\u003e\n\u003c!-- WARRANTY \u0026 BUYER ASSURANCE --\u003e\n\u003ch2 style=\"font-size: clamp(1.6rem,5.5vw,2.2rem); line-height: 1.2; margin: 6px 0 10px;\"\u003eWarranty \u0026amp; Buyer Assurance\u003c\/h2\u003e\n\u003cdiv style=\"background: #f6f8f6; border: 1px solid #e3e8e4; border-radius: 14px; padding: 18px; margin: 16px 0;\"\u003e\n\u003cul style=\"margin: 0; padding-left: 22px;\"\u003e\n\u003cli style=\"margin: 7px 0;\"\u003e\n\u003cstrong\u003e1-Year Warranty Parts \u0026amp; Labor\u003c\/strong\u003e — Coverage from date of purchase against manufacturer defects. Retain your receipt as proof of purchase for any warranty claim.\u003c\/li\u003e\n\u003cli style=\"margin: 7px 0;\"\u003e\n\u003cstrong\u003eFree 1-Year Technical Support\u003c\/strong\u003e — AIMS Power's own tech support team available at no charge for the first year.\u003c\/li\u003e\n\u003cli style=\"margin: 7px 0;\"\u003e\n\u003cstrong\u003eAuthorized Dealer\u003c\/strong\u003e — Purchased from TrueStead Supply, an authorized AIMS Power dealer. Your warranty is fully valid and supported.\u003c\/li\u003e\n\u003cli style=\"margin: 7px 0;\"\u003e\n\u003cstrong\u003e\u003ca style=\"color: #0a4a36;\" rel=\"noopener noreferrer\" href=\"https:\/\/www.truesteadsupply.com\/policies\/shipping-policy\" target=\"_blank\"\u003eFree Shipping\u003c\/a\u003e\u003c\/strong\u003e — Ships free to the contiguous US.\u003c\/li\u003e\n\u003cli style=\"margin: 7px 0;\"\u003e\n\u003cstrong\u003e\u003ca style=\"color: #0a4a36;\" rel=\"noopener noreferrer\" href=\"https:\/\/www.truesteadsupply.com\/pages\/returns-and-cancellations\" target=\"_blank\"\u003eReturns Policy\u003c\/a\u003e\u003c\/strong\u003e — Review our returns and cancellations policy for full details.\u003c\/li\u003e\n\u003cli style=\"margin: 7px 0;\"\u003e\n\u003cstrong\u003e\u003ca style=\"color: #0a4a36;\" rel=\"noopener noreferrer\" href=\"https:\/\/www.truesteadsupply.com\/pages\/best-price-guaranteed\" target=\"_blank\"\u003eBest Price Guarantee\u003c\/a\u003e\u003c\/strong\u003e — Found it lower? We'll beat it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #e3e8e4; margin: 34px 0;\"\u003e\n\u003c!-- MANUALS \u0026 DOCUMENTS --\u003e\n\u003ch2 style=\"font-size: clamp(1.6rem,5.5vw,2.2rem); line-height: 1.2; margin: 6px 0 10px;\"\u003eManuals \u0026amp; Documents\u003c\/h2\u003e\n\u003cdiv style=\"background: #f6f8f6; border: 1px solid #e3e8e4; border-radius: 14px; padding: 18px; margin: 16px 0;\"\u003e\n\u003cul style=\"margin: 0; padding-left: 22px; font-size: 1.05rem;\"\u003e\n\u003cli style=\"margin: 7px 0;\"\u003e\n\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0761\/5781\/2888\/files\/PWRIG700024048.pdf?v=1781262273\" target=\"_blank\"\u003e\u003cspan style=\"color: #0a4a36;\"\u003e\u003cb\u003eOwner's \/ Instruction Manual (PDF)\u003c\/b\u003e\u003c\/span\u003e\u003c\/a\u003e — Installation, wiring, frequency selection, operation, troubleshooting, and warranty details for the PWRIG700024048.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003chr style=\"border: 0; border-top: 1px solid #e3e8e4; margin: 34px 0;\"\u003e\n\u003c!-- FAQ --\u003e\n\u003ch2 style=\"font-size: clamp(1.6rem,5.5vw,2.2rem); line-height: 1.2; margin: 6px 0 10px;\"\u003eAIMS Power 7000W 48V Industrial Inverter — Frequently Asked Questions\u003c\/h2\u003e\n\u003cdetails open=\"\" style=\"border-top: 1px solid #e3e8e4;\"\u003e\n\u003csummary style=\"cursor: pointer; padding: 14px 4px; font-weight: 600; font-size: 1.15rem; color: #1b2520;\"\u003eHow does the 9-second surge differ from a standard inverter's surge?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 4px 14px; color: #5b6b63;\"\u003e\n\u003cp style=\"margin: 0;\"\u003eStandard consumer inverters sustain surge power for a fraction of a second — typically less than a second. The PWRIG700024048 electronically holds up to 14,000 watts for a full 9 seconds before shutting down. This extended window is critical for loads like air conditioners, large well pumps, and compressors that use locked-rotor startup — where the motor draws 4–5 times its running current for several seconds before reaching operating speed. During the surge period, the inverter's buzzer sounds as a warning; if the load exceeds 7000 watts beyond 9 seconds, the inverter will automatically shut down.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #e3e8e4;\"\u003e\n\u003csummary style=\"cursor: pointer; padding: 14px 4px; font-weight: 600; font-size: 1.15rem; color: #1b2520;\"\u003eWhy choose the 48V version over the 24V model at this wattage?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 4px 14px; color: #5b6b63;\"\u003e\n\u003cp style=\"margin: 0;\"\u003eAt 7000W output, a 48V inverter draws roughly half the DC current of an equivalent 24V model. Lower DC current means smaller cable gauge requirements, reduced voltage drop over longer cable runs, and the ability to wire multiple batteries together more efficiently. If your battery bank is already configured at 48V — common in larger off-grid solar systems — this is the direct match without additional voltage conversion equipment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #e3e8e4;\"\u003e\n\u003csummary style=\"cursor: pointer; padding: 14px 4px; font-weight: 600; font-size: 1.15rem; color: #1b2520;\"\u003eCan I pull 120V from one leg of this inverter's 240V output?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 4px 14px; color: #5b6b63;\"\u003e\n\u003cp style=\"margin: 0;\"\u003eNo. The PWRIG700024048 is a single-phase 240V inverter only. It does not produce two separate legs of 120V AC, and you cannot split the output to obtain 120V. All loads connected to this inverter must be rated for single-phase 240V. For 120V AC applications, see AIMS Power's standard 120V inverter range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #e3e8e4;\"\u003e\n\u003csummary style=\"cursor: pointer; padding: 14px 4px; font-weight: 600; font-size: 1.15rem; color: #1b2520;\"\u003eHow do I select 50Hz or 60Hz, and when do I need each?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 4px 14px; color: #5b6b63;\"\u003e\n\u003cp style=\"margin: 0;\"\u003eA front-panel switch toggles output frequency between 60Hz and 50Hz. Use 60Hz for North American loads and equipment. Use 50Hz for equipment designed for European, African, UK, Australian, or most international power standards. Set the frequency before connecting loads and powering the inverter — do not switch frequencies under load.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #e3e8e4;\"\u003e\n\u003csummary style=\"cursor: pointer; padding: 14px 4px; font-weight: 600; font-size: 1.15rem; color: #1b2520;\"\u003eWhy use the terminal block instead of the 240V outlet for heavy loads?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 4px 14px; color: #5b6b63;\"\u003e\n\u003cp style=\"margin: 0;\"\u003eThe standard universal 240V AC receptacle is rated for approximately 1500 watts — suitable for lower-draw plug-in equipment. For loads that approach or exceed 1500W, the AC direct-connect terminal block is required; it can carry the inverter's full 7000W continuous output to hardwired equipment like well pumps, compressors, and industrial machinery. Attempting to run full-load equipment through the standard outlet risks overloading the outlet itself.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #e3e8e4;\"\u003e\n\u003csummary style=\"cursor: pointer; padding: 14px 4px; font-weight: 600; font-size: 1.15rem; color: #1b2520;\"\u003eWhat does the DC voltmeter on the front panel show?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 4px 14px; color: #5b6b63;\"\u003e\n\u003cp style=\"margin: 0;\"\u003eThe front-panel DC voltmeter displays your 48V battery bank's voltage in real time. This lets you monitor battery state of charge at a glance and avoid running the system down toward the 41.5V low-voltage shutdown threshold. Combined with the percent-load LED bar, it gives operators a complete picture of both input (battery) and output (load) conditions without needing a separate monitoring device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #e3e8e4;\"\u003e\n\u003csummary style=\"cursor: pointer; padding: 14px 4px; font-weight: 600; font-size: 1.15rem; color: #1b2520;\"\u003eWhat battery bank do I need for this inverter?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 4px 14px; color: #5b6b63;\"\u003e\n\u003cp style=\"margin: 0;\"\u003eAt 7000W from a 48V battery bank, DC current draw is approximately 165A at full load — meaningfully lower than the 24V version's draw at the same wattage. A deep-cycle AGM or lithium battery bank at 48V, typically 200Ah or more, provides meaningful sustained runtime. Use short, appropriately-gauged DC cables and an inline ANL fuse rated for your cable size on the positive cable run. For solar-supplemented systems, size your panel array and charge controller to replenish the draw during the day.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003cdetails style=\"border-top: 1px solid #e3e8e4; border-bottom: 1px solid #e3e8e4;\"\u003e\n\u003csummary style=\"cursor: pointer; padding: 14px 4px; font-weight: 600; font-size: 1.15rem; color: #1b2520;\"\u003eWhat warranty and support come with this inverter?\u003c\/summary\u003e\n\u003cdiv style=\"padding: 0 4px 14px; color: #5b6b63;\"\u003e\n\u003cp style=\"margin: 0;\"\u003eThis inverter is backed by a 1-year parts and labor warranty from date of purchase, plus free technical support for the first year from AIMS Power's dedicated tech team. As an authorized AIMS Power dealer, TrueStead Supply ensures your warranty is valid from day one.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e","brand":"Aims Power","offers":[{"title":"Default Title","offer_id":49232298311832,"sku":"PWRIG700024048","price":1390.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0761\/5781\/2888\/files\/pwrig700024048yahoo.webp?v=1781262168","url":"https:\/\/www.truesteadsupply.com\/products\/aims-7000w-48v-240v-industrial-inverter","provider":"TrueStead Supply","version":"1.0","type":"link"}